MDS-C1-SPH-185
The Mitsubishi MDS-C1-SPH-185 spindle drive is engineered for high performance. It delivers a rated output power of 15 kW. The output voltage is 155 AC, with a rated current of 79 A. This spindle drive is a robust and efficient component. It is perfect for industrial applications needing reliable and powerful performance.
Technical Specifications:
The input voltage for the MDS-C1-SPH-185 ranges from 270 to 311 DC. The rated current is 95 A. The control power specifications include a voltage range of 200/200 to 230 AC, a frequency of 50/60 Hz, and a maximum current of 0.2 A. These features ensure stable and efficient operation under various conditions.
The spindle drive can manage a rush current of up to 35 A. The maximum rush conductivity time is 6 ms. The earth leakage current is specified at 6 mA, with a maximum of 15 mA. These safety features are essential for preventing potential electrical hazards during operation.
The MDS-C1-SPH-185 uses a sine wave PWM control method and a current control method. These methods offer precise and efficient control of the spindle motor. The regenerative braking feature enhances energy efficiency by converting kinetic energy back into electrical energy during deceleration. This reduces overall energy consumption and improves sustainability.
External Analog Output:
The external analogue output of the MDS-C1-SPH-185 offers a range of 0 to +10V across two channels. These channels support speed meter output and load meter output. They provide data for various adjustments. This feature allows for comprehensive monitoring and fine-tuning of the spindle drive’s performance. It ensures optimal operation tailored to specific needs.
The spindle drive has an overall protection rating of IP20. The terminal block TE1 is rated at IP00. It provides adequate protection against dust and accidental contact. It enhances the durability and safety of the device. The cooling method employed is forced wind cooling. This helps maintain optimal operating temperatures. It prevents overheating during prolonged use.
Additional Features:
Weighing 5.7 kg, the MDS-C1-SPH-185 is relatively lightweight for its capabilities. It makes it easier to handle and install. It reduces overall installation time and effort. The spindle drive radiates 342 W of heat at rated output. This ensures efficient heat dissipation. It maintains performance stability even under heavy loads.
The noise level of the spindle drive is kept under 55 dB. This ensures a quieter operation environment. This is particularly important in settings where noise pollution needs to be minimized. It enhances the comfort and safety of personnel.
The Mitsubishi MDS-C1-SPH-185 is a highly efficient and reliable component. Its advanced control methods, safety features, and robust design make it an excellent choice for enhancing the performance and efficiency of industrial operations. This spindle drive is a vital part of modern industrial machinery.
Frequently Asked Questions:
What are the input voltage and current requirements for the Mitsubishi MDS-C1-SPH-185 spindle drive?
The input voltage for the MDS-C1-SPH-185 ranges from 270 to 311 DC with a rated current of 95 A. These specifications ensure stable and efficient operation under various conditions.
What is the noise level of the Mitsubishi MDS-C1-SPH-185 spindle drive?
The noise level of the MDS-C1-SPH-185 is kept under 55 dB. This ensures a quieter operating environment, which is particularly important in settings where noise pollution needs to be minimized for the comfort and safety of personnel.
What are the cooling and protection features of the Mitsubishi MDS-C1-SPH-185 spindle drive?
The MDS-C1-SPH-185 uses forced wind cooling to maintain optimal temperatures and prevent overheating. It has an IP20 overall protection rating and an IP00 rating for the terminal block TE1 for ensuring durability and safety against dust and accidental contact.
Product Specifications Table
Attribute | Specifications |
---|---|
Output Power | 15 kW |
Rated Voltage (Output) | 155 AC |
Rated Current (Output) | 79 A |
Rated Voltage (Input) | 270 to 311 DC |
Rated Current (Input) | 95 A |
Control Power Voltage | 200/200 to 230 AC |
Control Power Frequency | 50/60 Hz |
Earth Leakage Current | 6 mA (Max. 15 mA) |
Control Method | Sine wave PWM control method, current control method |
Cooling Method | Forced wind cooling |