Siemens 6SL3210-1PE26-0UL0
The Siemens Power Module 6SL3210-1PE26-0UL0 is a robust and efficient device. It operates in a wide ambient temperature range from -20 to 40 °C in Low Overload (LO) and -20 to 50 °C in High Overload (HO). The module uses internal air cooling, with a cooling air requirement of 0.055 m³/s. The internal air-cooling system ensures reliable operation under varying temperature conditions.
Connections:
On the line side, the Siemens Power Module 6SL3210-1PE26-0UL0 features screw-type terminals. The conductor cross-section for line connections ranges from 10.00 to 35.00 mm². The motor end also uses screw-type terminals with the same conductor cross-section specifications. This design facilitates secure and efficient electrical connections.
For the DC link intended for braking resistors, the screw-type terminals support conductor cross-sections from 2.50 to 16.00 mm². The maximum cable length for connections is 10 meters. The PE connection also utilizes screw-type terminals, ensuring reliable grounding. These connection features contribute to the module’s versatility and ease of installation in various applications.
Input Specifications:
The input section of the Siemens 6SL3210-1PE26-0UL0 operates on a 3 AC phase system. It supports a line voltage range of 380 to 480 V with a tolerance of ±10%. The line frequency ranges from 47 to 63 Hz. This wide range of input specifications ensures compatibility with different industrial power systems.
The rated current for LO is 57.00 A, while for HO, it is 47.00 A. The power factor is 0.95, and the offset factor is cos ? 0.99, indicating high efficiency. The module’s efficiency is further demonstrated by its high-power factor and low offset factor. These specifications ensure that the module operates effectively, reducing energy losses and enhancing performance.
Output Specifications:
The output section also operates on a 3 AC phase system. The rated voltage is 400V as per IEC standards and 480V according to NEC. The rated power for LO is 30.00 kW or 40.00 hp, and for HO, it is 22.00 kW or 30.00 hp. These ratings ensure that the module can handle substantial loads, making it suitable for various industrial applications.
The rated current for LO is 60.00 A, while for HO, it is 45.00 A. The maximum output current is 90.00 A. The module operates at a pulse frequency of 4 kHz. These output specifications provide the necessary power and current ratings for demanding applications. The high pulse frequency ensures smooth and efficient operation.
The Siemens Power Module 6SL3210-1PE26-0UL0 has a degree of protection rated at IP20 and is classified as a UL open type. It has a frame size of FSD and a net weight of 17.00 kg. These mechanical data points highlight the module’s robust construction and suitability for industrial environments. The IP20 rating ensures protection against solid objects, while the frame size and weight make it manageable for installation and maintenance.
Frequently Asked Questions:
What is the operating temperature range of the Siemens Power Module 6SL3210-1PE26-0UL0?
The Siemens Power Module 6SL3210-1PE26-0UL0 operates in a wide ambient temperature range from -20 to 40 °C in LO and -20 to 50 °C in HO. This ensures reliable performance under varying environmental conditions.
What type of connections does the Siemens Power Module 6SL3210-1PE26-0UL0 use?
The module features screw-type terminals for line side, motor end, DC link, and PE connections. The conductor cross-section for line and motor connections ranges from 10.00 to 35.00 mm², and for the DC link, it ranges from 2.50 to 16.00 mm².
What are the input voltage and frequency specifications of the Siemens Power Module 6SL3210-1PE26-0UL0?
The input section operates on a 3 AC phase system, supporting a line voltage range of 380 to 480 V with a tolerance of ±10%. The line frequency ranges from 47 to 63 Hz, ensuring compatibility with various industrial power systems.
Product Specifications Table
Attribute | Specifications |
---|---|
Manufacturer | Siemens |
Ambient Temperature (Operation HO) | -20 … 50 °C (-4 … 122 °F) |
Cooling | Internal air cooling |
Cooling Air Requirement | 0.055 m³/s (1.942 ft³/s) |
Line Voltage | 380 … 480 V ±10 % |
Rated Current (LO) | 57.00 A |
Rated Current (HO) | 47.00 A |
Rated Power (LO) | 30.00 kW / 40.00 hp |
Rated Power (HO) | 22.00 kW / 30.00 hp |
Efficiency (?) | 0.98 |